BD
LOOPS
For installation under asphalt, pavers, or in concrete - 14 AWG
loop wire design for superior performance Pre tested 3 ways with
meg-ohm meter, inductance tester and live detector Installation
kit includes: cable ties, ground stakes, and loop lead-in labels
- EZ installation guide Loop wire meets UL standard 493 for direct
burial - Pre-phased at factory for EZ hoop-up Made in the USA |
|
 |
|

|

|

|

|
| |
|
|
Prefabricated Loops
RL24-40 Prefabricated Loop 4ft x 8ft RL32-40
Prefabricated Loop 6ft x 10ft RL36-40
Prefabricated Loop 6ft x 12ft RL44-40
Prefabricated Loop 6ft x 16ft RL52-40
Prefabricated Loop 6ft x 20ft EL24-60
Prefabricated Loop 4ft x 8ft EL32-60
Prefabricated Loop 6ft x 10ft |
EL36-60 Prefabricated Loop 6ft x 12ft
EL44-60 Prefabricated Loop 6ft x 16ft EL52-60
Prefabricated Loop 6ft x 20ft EL24-100
Prefabricated Loop 4ft x 8ft EL32-100
Prefabricated Loop 6ft x 10ft EL36-100
Prefabricated Loop 6ft x 12ft EL44-100
Prefabricated Loop 6ft x 16ft EL52-100
Prefabricated Loop 6ft x 20ft |
|

|

|

|

|
| |
BDL E-Z E-Z Detector Cheker and E-Z Detector Cheker Jr. ( without
green LED )  |
|
Small compact design that fits in your hand
Color-coded clip/test leads store in base unit
Green LED lights when detector is properly energizing the loop circuit
(N/A on Jr.)
Push RED button test to see if detector is picking up a trip
Eliminates the need for a Mega OHM meter
Allows for harness wiring check from detector to loop terminals within
the gate operator
Eliminates the need to stock the service truck with so many difference
types of detectors
Saves valuable time in trouble shooting in the field
Reduces the chance of cutting in a new loop
Never needs battery replacament.
Protective fuse to safeguard unit if cannected to 110V
Allows the opportunity to increase your profits by reducing your servicing
time and reducing repeat service calls
No air chamber in loop coil design
No chance of phantom detection from ground vibrations
No chance of loop coil floating to the surface during concrete pour
No chance of reducing structural design of concrete because
of loop coil air pocket |
|

|

|

|

|
| |
|
|
ABOUT
TYPE UF-B UNDERGROUND CABLE UF-B Underground
Feeder Cable's construction provides solid or stranded Type THHN/THWN
conductors laid parallel with or without an uninsulated grounding
conductor. An outer jacket of tough polyvinyl chloride (PVC), applied
directly over the assembled conductors, provides protection against
mechanical damage, moisture, chemicals and corosion. |
|

|

|

|

|
| |
APPLICATIONS:
Permitted for use underground including direct burial in earth as
Feeder or Branch Circuit Cable where provided with overcurrent protection
For use in interior wiring in wet, dry or corrosive locations under
the recognized wiring methods of the National Electrical Code (NEC)
Accaptable to be installed as a Non-Metalic Sheathed Cable in accordance
with NEC Article 340.10(4)
Acceptable for use in accordance with NEC Articles 300.4(B) and 340
FUTURES:
Ul listed as type UF-B for direct burial E25682
Grease and chemical resisitant conductors
Crush resistant
Moisture, chemical and sunlight resistant jacket
Conductors rated 90°C
The amplicity shall be that of 60°C conductors and comply with
NEC section 300.15 CONSTRUCTION:
Conductors: Solid (per ASTM B-3) or stranded soft annealed uncoated
copper (per ASTM B-8)
Insulation: Polyvinyl chloride (PVC) conpound to thickness required
by Underwriters Laboratories for Type THHN 90°C rated
Color Code:
2 Conductors: Black, White
3 Conductors: Black, White, Red
Conductor Jacket: Heat stabilized nylon
Grounding Conductor: Uninsulated, soft annealed solid
Assembly: Individual Type THHN/THWN conductors are laid parallel with
(or without) a grounding conductor it is placed in the web between
insluated conductors
Temperature: 60°C wet or dry
Rating: 600V
SPECIFIC & STANDARDS:
UL Standard 493 - Thermoplastic Insulated Underground Feeder and
Branch Circuit Cables |
|

|

|

|

|
| |