Seco Larm SK-1123-SPQ - 1100-User Vandal-Resistant Outdoor Access Control Keypad w/Proximity Reader
Item No. SEA SK-1123-SPQ
Features 1,100 Users over 2 Outputs. Codes may be 4~8 digits: – Output #1 – Form C relay, 1A@30VDC, 1,000 users – Output #2 – Form C relay, 1A@30VDC, 100 users Outputs can be programmed to activate for up to 99,999 seconds (nearly 28 hours) Super user code gives admin access to keypad Up to 50 (01~5
Description
Features
- 1,100 Users over 2 Outputs. Codes may be 4~8 digits: – Output #1 – Form C relay, 1A@30VDC, 1,000 users – Output #2 – Form C relay, 1A@30VDC, 100 users
- Outputs can be programmed to activate for up to 99,999 seconds (nearly 28 hours)
- Super user code gives admin access to keypad
- Up to 50 (01~50) possible temporary visitor codes, which can be programmed for one-time or limited-time use (1~99 hours)
- Programmable egress input with optional warning alarm and delayed egress
- Real-time clock to auto-disable access at specific times
- Up to 50 (01~50) duress codes for output #1 and 10 (01~10) for output #2
- Duress code signals a silent alarm if an authorized user is forced to open the door under duress
- 12~24 VDC/VAC Auto-adjusting operation
- All features are programmed directly from the keypad: No need for an external programmer
- IP66 Weatherproof Rating
- Mounts to a standard single-gang back box (surface-mount back box included)
- Durable and attractive stainless steel faceplate
- Tamper output: N.C. Dry contact, 50mA@24VDC max.
- Keypad illuminates when a button is pressed; backlight can be programmed for FULL, AUTO, or OFF in standby mode
- Mantrap: for a protected area with two doors, this feature allows only one door to be open at a time
- Door sensor input for anti-tailgating operation
- Door-propped-open warning
- Door-forced-open warning
- EEPROM Memory protects programmed information in case of power loss
- Type Vandal-Resistant Outdoor Digital Access Keypad with Built-in Prox Reader
- Operating Voltage 12~24 VDC/VAC
- Current Draw – Standby 66mA@12VDC
- Current Draw – Keypress 93mA@12VDC
- Current Draw- 1 Relay Active 99mA@12VDC
- Current Draw – Total Max 160mA@12VDC
- Current Draw- 1 & 2 Relays Active 126mA@12VDC
- Relay Output- #1 1A@30VDC, Form C
- Relay Output- #2 1A@30VDC, Form C
- Relay Output- Key Active 100mA@24VDC
- Relay Output- Duress 100mA@24VDC
- Relay Output- Interlock 100mA@24VDC
- Relay Output- Tamper 50mA@24VDC
- Egress Inputs N.O. Ground
- Door Inhibit Input N.O. Ground
- Door Sensor Input N.C. Ground
- Proximity Reader Frequency 125kHz (EM125)
- Proximity Reader Sensing Distance 1-1/2” (38mm)
- Operating Temperature -4°~158° F (-20°~70° C)
- Operating Humidity 5~95% Non-condensing
- Dimensions 4-15/16”x3-1/8”x2-1/16” (125x79x52 mm)
- Weight 1-lb, 2-oz (520g)
- IP Rating Weatherproof IP66
Specifications
- Vendor Item No.
- SK-1123-SPQ
- Item Category Code
- ACCESS CONTROL
Seco Larm SK-1123-SPQ - 1100-User Vandal-Resistant Outdoor Access Control Keypad w/Proximity Reader
Item No. SEA SK-1123-SPQ
Features 1,100 Users over 2 Outputs. Codes may be 4~8 digits: – Output #1 – Form C relay, 1A@30VDC, 1,000 users – Output #2 – Form C relay, 1A@30VDC, 100 users Outputs can be programmed to activate for up to 99,999 seconds (nearly 28 hours) Super user code gives admin access to keypad Up to 50 (01~5
Description
Features
- 1,100 Users over 2 Outputs. Codes may be 4~8 digits: – Output #1 – Form C relay, 1A@30VDC, 1,000 users – Output #2 – Form C relay, 1A@30VDC, 100 users
- Outputs can be programmed to activate for up to 99,999 seconds (nearly 28 hours)
- Super user code gives admin access to keypad
- Up to 50 (01~50) possible temporary visitor codes, which can be programmed for one-time or limited-time use (1~99 hours)
- Programmable egress input with optional warning alarm and delayed egress
- Real-time clock to auto-disable access at specific times
- Up to 50 (01~50) duress codes for output #1 and 10 (01~10) for output #2
- Duress code signals a silent alarm if an authorized user is forced to open the door under duress
- 12~24 VDC/VAC Auto-adjusting operation
- All features are programmed directly from the keypad: No need for an external programmer
- IP66 Weatherproof Rating
- Mounts to a standard single-gang back box (surface-mount back box included)
- Durable and attractive stainless steel faceplate
- Tamper output: N.C. Dry contact, 50mA@24VDC max.
- Keypad illuminates when a button is pressed; backlight can be programmed for FULL, AUTO, or OFF in standby mode
- Mantrap: for a protected area with two doors, this feature allows only one door to be open at a time
- Door sensor input for anti-tailgating operation
- Door-propped-open warning
- Door-forced-open warning
- EEPROM Memory protects programmed information in case of power loss
- Type Vandal-Resistant Outdoor Digital Access Keypad with Built-in Prox Reader
- Operating Voltage 12~24 VDC/VAC
- Current Draw – Standby 66mA@12VDC
- Current Draw – Keypress 93mA@12VDC
- Current Draw- 1 Relay Active 99mA@12VDC
- Current Draw – Total Max 160mA@12VDC
- Current Draw- 1 & 2 Relays Active 126mA@12VDC
- Relay Output- #1 1A@30VDC, Form C
- Relay Output- #2 1A@30VDC, Form C
- Relay Output- Key Active 100mA@24VDC
- Relay Output- Duress 100mA@24VDC
- Relay Output- Interlock 100mA@24VDC
- Relay Output- Tamper 50mA@24VDC
- Egress Inputs N.O. Ground
- Door Inhibit Input N.O. Ground
- Door Sensor Input N.C. Ground
- Proximity Reader Frequency 125kHz (EM125)
- Proximity Reader Sensing Distance 1-1/2” (38mm)
- Operating Temperature -4°~158° F (-20°~70° C)
- Operating Humidity 5~95% Non-condensing
- Dimensions 4-15/16”x3-1/8”x2-1/16” (125x79x52 mm)
- Weight 1-lb, 2-oz (520g)
- IP Rating Weatherproof IP66
Specifications
- Vendor Item No.
- SK-1123-SPQ
- Item Category Code
- ACCESS CONTROL