BD LOOPS SC40-50 - Preformed 3/16" Saw-Cut 6'x14' Loop w/50' lead-in
Item No. BD SC40-50
Loop length: 40 ft. Loop area of coverage: 6 ft. by 14 ft. Lead-in length: 50 ft. BD Loops Preformed Saw-Cut Inductance Loops are a complete loop with a set size loop and length of lead-in run. Our Saw-Cut Loops have an extra layer of protection: a durable outer jacket that protects and tightly
Description
Loop length: 40 ft.
Loop area of coverage: 6 ft. by 14 ft.
Lead-in length: 50 ft.
BD Loops Preformed Saw-Cut Inductance Loops are a complete loop with a set size loop and length of lead-in run. Our Saw-Cut Loops have an extra layer of protection: a durable outer jacket that protects and tightly binds the inner conductors. Used for saw-cut installations where a 3/16” or wider slot is cut into the concrete or asphalt and the loop wire is stuffed into the saw-cut slot and sealed with loop sealant. All BD Loops are made with 16 AWG copper wire and rated for direct burial use.
SUPERIOR FEATURES:
Loop area of coverage: 6 ft. by 14 ft.
Lead-in length: 50 ft.
BD Loops Preformed Saw-Cut Inductance Loops are a complete loop with a set size loop and length of lead-in run. Our Saw-Cut Loops have an extra layer of protection: a durable outer jacket that protects and tightly binds the inner conductors. Used for saw-cut installations where a 3/16” or wider slot is cut into the concrete or asphalt and the loop wire is stuffed into the saw-cut slot and sealed with loop sealant. All BD Loops are made with 16 AWG copper wire and rated for direct burial use.
SUPERIOR FEATURES:
- Extra layer of protection—Thick and durable outer jacket protects both loop and lead-in.
- Each loop is tested 3 ways before it leaves the factory.
- Backer-rod is built into the wire! No need to use backer-rod if the loop is installed in a 3/16” saw-cut groove.
- Lead-in wires are tightly bound in a protective outer jacket. Eliminating the need for twisting.
- Both loop and lead-in fit into a 3/16” wide saw-cut groove. No more double cutting the lead-in run!
- Loop fills up a larger percentage of the saw-cut groove, requires less loop sealant to seal the groove. (30-40% less sealant vs a 1/4” wide groove)
- Cuts don’t need to be exact! Any BD Loop can be made up to 4’ smaller. Be slightly conservative with your cuts and BD Loops Preformed Saw-Cut Loops will fit every time.
- Use the BD-LS flat 3/16″ sealant tip and seal the loop in just 1 pass. No more waiting around for the sealant to seep in and top off gaps. Make an attractive smooth and even seal.
Specifications
- Vendor Item No.
- SC40-50
- Item Category Code
- SAFETY
BD LOOPS SC40-50 - Preformed 3/16" Saw-Cut 6'x14' Loop w/50' lead-in
Item No. BD SC40-50
Loop length: 40 ft. Loop area of coverage: 6 ft. by 14 ft. Lead-in length: 50 ft. BD Loops Preformed Saw-Cut Inductance Loops are a complete loop with a set size loop and length of lead-in run. Our Saw-Cut Loops have an extra layer of protection: a durable outer jacket that protects and tightly
Description
Loop length: 40 ft.
Loop area of coverage: 6 ft. by 14 ft.
Lead-in length: 50 ft.
BD Loops Preformed Saw-Cut Inductance Loops are a complete loop with a set size loop and length of lead-in run. Our Saw-Cut Loops have an extra layer of protection: a durable outer jacket that protects and tightly binds the inner conductors. Used for saw-cut installations where a 3/16” or wider slot is cut into the concrete or asphalt and the loop wire is stuffed into the saw-cut slot and sealed with loop sealant. All BD Loops are made with 16 AWG copper wire and rated for direct burial use.
SUPERIOR FEATURES:
Loop area of coverage: 6 ft. by 14 ft.
Lead-in length: 50 ft.
BD Loops Preformed Saw-Cut Inductance Loops are a complete loop with a set size loop and length of lead-in run. Our Saw-Cut Loops have an extra layer of protection: a durable outer jacket that protects and tightly binds the inner conductors. Used for saw-cut installations where a 3/16” or wider slot is cut into the concrete or asphalt and the loop wire is stuffed into the saw-cut slot and sealed with loop sealant. All BD Loops are made with 16 AWG copper wire and rated for direct burial use.
SUPERIOR FEATURES:
- Extra layer of protection—Thick and durable outer jacket protects both loop and lead-in.
- Each loop is tested 3 ways before it leaves the factory.
- Backer-rod is built into the wire! No need to use backer-rod if the loop is installed in a 3/16” saw-cut groove.
- Lead-in wires are tightly bound in a protective outer jacket. Eliminating the need for twisting.
- Both loop and lead-in fit into a 3/16” wide saw-cut groove. No more double cutting the lead-in run!
- Loop fills up a larger percentage of the saw-cut groove, requires less loop sealant to seal the groove. (30-40% less sealant vs a 1/4” wide groove)
- Cuts don’t need to be exact! Any BD Loop can be made up to 4’ smaller. Be slightly conservative with your cuts and BD Loops Preformed Saw-Cut Loops will fit every time.
- Use the BD-LS flat 3/16″ sealant tip and seal the loop in just 1 pass. No more waiting around for the sealant to seep in and top off gaps. Make an attractive smooth and even seal.
Specifications
- Vendor Item No.
- SC40-50
- Item Category Code
- SAFETY