EMX ULT-PLG - Two-Channel Multi-Voltage Plug-In Style Vehicle Loop Detector
Item No. EMX ULT-PLG
ULT-PLG works on Pre-UL SL3000, CSW200. The ULTRA-PLG vehicle loop detector combines small size with full-featured functionality in a plug-in module. This detector features DETECT-ON-STOP™ or (DOS) technology, which allows detection only when a vehicle has come to a complete stop on the loop. This e
Description
ULT-PLG works on Pre-UL SL3000, CSW200.
The ULTRA-PLG vehicle loop detector combines small size with full-featured functionality in a plug-in module.
This detector features DETECT-ON-STOP™ or (DOS) technology, which allows detection only when a vehicle has come to a complete stop on the loop. This exclusive feature is unique to EMX and is a major advantage if you want to ignore cross traffic in tight spaces.
The ULT-PLG provides a solid-state output indicating vehicle presence. The second output can be used for presence, loop fault or pulse on entry/pulse on exit. Our latest vehicle detector provides options for automatic sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite and normal (5 min.) presence.
This detector is easy to install and operate. Sensitivity selection is simplified by the ULTRAMETER™. Ten sensitivity settings allow for finer adjustment of the detection level. The four frequency selections help to prevent crosstalk in multi-loop applications.
The ULT-PLG is compatible with a wide variety of gate operators. Please see the Data Sheet for a detailed list.
When you choose our ULTRA-PLG for your vehicle, you can count on the following advantages:
The ULTRA-PLG vehicle loop detector combines small size with full-featured functionality in a plug-in module.
This detector features DETECT-ON-STOP™ or (DOS) technology, which allows detection only when a vehicle has come to a complete stop on the loop. This exclusive feature is unique to EMX and is a major advantage if you want to ignore cross traffic in tight spaces.
The ULT-PLG provides a solid-state output indicating vehicle presence. The second output can be used for presence, loop fault or pulse on entry/pulse on exit. Our latest vehicle detector provides options for automatic sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite and normal (5 min.) presence.
This detector is easy to install and operate. Sensitivity selection is simplified by the ULTRAMETER™. Ten sensitivity settings allow for finer adjustment of the detection level. The four frequency selections help to prevent crosstalk in multi-loop applications.
The ULT-PLG is compatible with a wide variety of gate operators. Please see the Data Sheet for a detailed list.
When you choose our ULTRA-PLG for your vehicle, you can count on the following advantages:
- ULTRAMETER™ displays optimum sensitivity setting/crosstalk interference
- Frequency count/reset switch
- 10 sensitivity settings
- 4 operating frequencies
- Solid-state output
- Second output, pulse entry/exit, normal/infinite presence
- CE compliant
- DETECT-ON-STOP™ allows detection only when a vehicle has come to a complete stop on the loop
- Sensitivity:Â 10 levels, 0-9
- UltraMETER™ display: Indicates optimum sensitivity level, 0-9 diagnostic aid
- Loop frequency:Â 4 settings (low, med-low, med-hi, high)
- Loop inductance: 20…2000µH (Q factor > 5)
- Grounded loop:Â Isolation transformer allows operation with poor quality loops
- Automatic tuning:Â Detector tunes to loop on power-up and following frequency count function
- Environmental tracking:Â Automatic compensation
- Surge protection:Â Loop circuitry protected by surge suppressors
- Detect output:Â Solid-state (open collector)
- Output B:Â Solid-state (open collector)
- Output B inverted:Â Solid-state (open collector)
- Power / loop fault indicator:Â Green LED
- Detect / frequency count indicator: Red LED
- Detect-on-Stop:Â Requires vehicle to stop for a minimum of 1 second (1-2s typical)
- ASB (Automatic Sensitivity Boost):Â Increases sensitivity after initial detection to prevent dropout due to high bed vehicles
- Power: 12VDC…24VDC
- Operating current: 15 mA
- Operating temperature: -40°C…82°C (-40°F…180°F) 0…95% relative humidity
- Dimensions (L x W x H):  3.0” (76mm) x 0.9” (22mm) x 2.75” (70mm) Weight: 0.15 lbs. (68 g)
- Connector:Â 10-pin female
Specifications
- Vendor Item No.
- ULT-PLG
- Item Category Code
- SAFETY
- Description 6
- EMXINDUSTRIES
EMX ULT-PLG - Two-Channel Multi-Voltage Plug-In Style Vehicle Loop Detector
Item No. EMX ULT-PLG
ULT-PLG works on Pre-UL SL3000, CSW200. The ULTRA-PLG vehicle loop detector combines small size with full-featured functionality in a plug-in module. This detector features DETECT-ON-STOP™ or (DOS) technology, which allows detection only when a vehicle has come to a complete stop on the loop. This e
Description
ULT-PLG works on Pre-UL SL3000, CSW200.
The ULTRA-PLG vehicle loop detector combines small size with full-featured functionality in a plug-in module.
This detector features DETECT-ON-STOP™ or (DOS) technology, which allows detection only when a vehicle has come to a complete stop on the loop. This exclusive feature is unique to EMX and is a major advantage if you want to ignore cross traffic in tight spaces.
The ULT-PLG provides a solid-state output indicating vehicle presence. The second output can be used for presence, loop fault or pulse on entry/pulse on exit. Our latest vehicle detector provides options for automatic sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite and normal (5 min.) presence.
This detector is easy to install and operate. Sensitivity selection is simplified by the ULTRAMETER™. Ten sensitivity settings allow for finer adjustment of the detection level. The four frequency selections help to prevent crosstalk in multi-loop applications.
The ULT-PLG is compatible with a wide variety of gate operators. Please see the Data Sheet for a detailed list.
When you choose our ULTRA-PLG for your vehicle, you can count on the following advantages:
The ULTRA-PLG vehicle loop detector combines small size with full-featured functionality in a plug-in module.
This detector features DETECT-ON-STOP™ or (DOS) technology, which allows detection only when a vehicle has come to a complete stop on the loop. This exclusive feature is unique to EMX and is a major advantage if you want to ignore cross traffic in tight spaces.
The ULT-PLG provides a solid-state output indicating vehicle presence. The second output can be used for presence, loop fault or pulse on entry/pulse on exit. Our latest vehicle detector provides options for automatic sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite and normal (5 min.) presence.
This detector is easy to install and operate. Sensitivity selection is simplified by the ULTRAMETER™. Ten sensitivity settings allow for finer adjustment of the detection level. The four frequency selections help to prevent crosstalk in multi-loop applications.
The ULT-PLG is compatible with a wide variety of gate operators. Please see the Data Sheet for a detailed list.
When you choose our ULTRA-PLG for your vehicle, you can count on the following advantages:
- ULTRAMETER™ displays optimum sensitivity setting/crosstalk interference
- Frequency count/reset switch
- 10 sensitivity settings
- 4 operating frequencies
- Solid-state output
- Second output, pulse entry/exit, normal/infinite presence
- CE compliant
- DETECT-ON-STOP™ allows detection only when a vehicle has come to a complete stop on the loop
- Sensitivity:Â 10 levels, 0-9
- UltraMETER™ display: Indicates optimum sensitivity level, 0-9 diagnostic aid
- Loop frequency:Â 4 settings (low, med-low, med-hi, high)
- Loop inductance: 20…2000µH (Q factor > 5)
- Grounded loop:Â Isolation transformer allows operation with poor quality loops
- Automatic tuning:Â Detector tunes to loop on power-up and following frequency count function
- Environmental tracking:Â Automatic compensation
- Surge protection:Â Loop circuitry protected by surge suppressors
- Detect output:Â Solid-state (open collector)
- Output B:Â Solid-state (open collector)
- Output B inverted:Â Solid-state (open collector)
- Power / loop fault indicator:Â Green LED
- Detect / frequency count indicator: Red LED
- Detect-on-Stop:Â Requires vehicle to stop for a minimum of 1 second (1-2s typical)
- ASB (Automatic Sensitivity Boost):Â Increases sensitivity after initial detection to prevent dropout due to high bed vehicles
- Power: 12VDC…24VDC
- Operating current: 15 mA
- Operating temperature: -40°C…82°C (-40°F…180°F) 0…95% relative humidity
- Dimensions (L x W x H):  3.0” (76mm) x 0.9” (22mm) x 2.75” (70mm) Weight: 0.15 lbs. (68 g)
- Connector:Â 10-pin female
Specifications
- Vendor Item No.
- ULT-PLG
- Item Category Code
- SAFETY
- Description 6
- EMXINDUSTRIES